2224 CHAPTER 145: BACKUP CENTER CONFIGURATION COMMANDS
■ This command and the standby interface command cannot be configured at
the same time. That is, if you have configured the standby interface
command on the main interface, you cannot configure the standby track
command on both the main interface and its backup interface; if you have
associated an interface with a Track object, you cannot configure the interface
as the main interface or a backup interface.
■ One interface can be associated with one Track object. If you execute this
command repeatedly on one interface, the new configuration will overwrite
the original one.
■ You can associate an interface with a nonexistent Track object. The track
function can take effect after the Track object is created with the track
command.
Related commands: standby interface, track on page 2529.
n
Support for this command varies with devices.
Examples # Configure interface Serial 2/0 to be associated with Track object 1.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] standby track 1