1458 CHAPTER 92: MLD CONFIGURATION COMMANDS
By default, the MLD querier robustness variable is 2.
Related command: mld robust-count, last-listener-query-interval, timer other-querier-present
(MLD view), and display mld interface.
Example # Set the MLD querier robustness variable to 3 globally.
<Sysname> system-view
[Sysname] mld
[Sysname-mld] robust-count 3
send-router-alert (MLD view)
Syntax send-router-alert
undo send-router-alert
View MLD view
Parameter None
Description Use the
send-router-alert command to globally enable the insertion of the
Router-Alert option into MLD messages to be sent.
Use the
undo send-router-alert command to globally disable the insertion of
the Router-Alert option into MLD messages to be sent.
By default, MLD messages carry the Router-Alert option.
Related command: mld send-router-alert and require-router-alert (MLD view).
Example # Globally disable insertion of the Router-Alert option into MLD messages to be
sent.
<Sysname> system-view
[Sysname] mld
[Sysname-mld] undo send-router-alert
timer other-querier-present (MLD view)
Syntax timer other-querier-present interval
undo timer other-querier-present
View MLD view
Parameter interval: MLD other querier present interval in seconds, in the range of 60 to 300.