![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/8b/18b1e1e7-4363-4706-bb94-6eba3a993996/18b1e1e7-4363-4706-bb94-6eba3a993996-bgb2.png)
178 CHAPTER 9: CONFIGURATION COMMANDS FOR ETHERNET INTERFACES IN BRIDGE MODE
Member of group2:
None
# Display the details of the manual port group named group 1.
<Sysname> display port-group manual name group1
Member of group1:
Ethernet1/0 Ethernet1/1 Ethernet1/2
Ethernet1/3 Ethernet1/4 Ethernet1/5
Ethernet1/6 Ethernet1/7 Ethernet2/0
flow-interval
Syntax flow-interval interval
undo flow-interval
View System view
Parameter interval: Time interval at which interface statistics is collected, in the range of 5 to
300 seconds, a multiple of 5. The system default is 300 seconds.
Description Use the
flow-interval command to configure the time interval for collecting
interface statistics.
Use the
undo flow-interval command to restore the default interval.
Example # Set the time interval for collecting interface statistics to 100 seconds.
<Sysname> system-view
[Sysname] flow-interval 100
group-member
Syntax group-member interface-list
undo group-member interface-list
View Port group view
Parameters interface-list: Ethernet interface list, in the form of { interface-type
interface-number [ to interface-type interface-number ] } &<1-10>, where
&<1-10> indicates that you can specify up to 10 interfaces or interface ranges
Table 15 Description on the fields of the display port-group manual command
Field Description
Member of group Member ports of the manual port group