standby timer flow-check
Syntax standby timer flow-check interval
undo standby timer flow-check
View Interface view
Parameter interval: Specifies flow check interval, in the range 30 to 600 seconds.
Description Use the
standby timer flow-check command to configure the interval for
checking the traffic size on the main interface.
Use the
undo standby timer flow-check command to restore the default.
By default, the interval for checking the traffic size on the main interface is 30
seconds.
Note that this command can be executed after backup interfaces are specified.
Related command: standby interface.
Example # Configure load sharing, backup bandwidth and flow check interval on interface
Serial 2/0 to 60 seconds.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] standby timer flow-check 60
standby track
Syntax standby track track-entry-number
undo standby track
View Interface view
Parameters track-entry-number: Specifies a Track object to be monitored by its number, in the
range 1 to 1024.
Description Use the
standby track command to configure the association between an
interface and a Track object.
Use the
undo standby track command to remove the association.
By default, an interface is not associated with a Track object.
Note that: