1–24
AM700 Audio Measurement Set Service Manual
Table 1–14: Safety standards compliance (cont.)
Capabilities Description
Overvoltage Category Mains – Overvoltage Category II (as defined in IEC 1010-1, Annex J)
Analog Input – Overvoltage Category I
Pollution Degree Pollution Degree 2 (as defined in IEC 1010-1)
Note – Rated for indoor use only
Table 1–15: Environmental characteristics
Capabilities Description
Atmospherics
Temperature
Operating –10_ C to +50_ C, Class 5
Nonoperating (storage) –51_ C to +71_ C. Class 3
Humidity To 95% relative humidity at or below +55_ C
Altitude
Operating To 15,000 feet (4572 meters)
Maximum operating temperature to be decreased 1
d
C per 1000 feet
(305 meters) above 5000 feet (1524 meters).
Nonoperating (storage) To 50,000 feet (15240 meters)
Table 1–16: Dynamic characteristics
Capabilities Description
Vibration
Random Vibration Class 3 levels
Sinusoidal Vibration MIL-T-28800E, para. 4.5.5.3.1, Sinusoidal Vibration test, 5 Hz to 55 Hz.
Shock
Functional Shock 30 g, 11 ms, half-sine input
Transit Drop Nonoperating Transit Drop with 8-inch drops, front cover installed.
Bench Handling MIL-T-28800E, para. 4.5.5.4.3, Bench Handling test, with cabinet on and
instrument operating. Each edge lifted four inches and allowed to free fall
onto a solid wooden surface.
Packaged Product Drop Drop of 18 inches on each edge, face, and corner of packaged product;
additional drop of 36 inches on bottom face.
Warehouse Stacking Up to five units high