Polycom RMX 1500 Stereo Receiver User Manual


  Open as PDF
of 1010
 
Appendix H-Setting the MCU for Integration Into Microsoft Environment
Polycom, Inc. H-69
ICE Active Alarms
When ICE environment is enabled in the MCU, failure to communicate with a required
component triggers the display of an Active Alarm in the System Alerts pane.
The following table lists these active alarms:
Table 9 ICE Environment - MCU Active Alarms
Active Alarm Phase Alarm Displayed When Troubleshooting
ICE failure: Failed to
register with OCS.
Check the MCU
Server Name.
Registration The MCU did not receive
a confirmation response
from the OCS to the
Registration request.
Check that the MCU Server
Name in IP Network Service
- SIP Advanced is identical
to the User name defined
for the MCU in the OCS
Active Directory.
Make sure that the MCU
user is defined in the OCS
Active Directory.
ICE failure: Failed to
subscribe with the
OCS, therefore the
A/V Edge Server
URI was not
received.
Subscribe The MCU did not receive
a confirmation response
from the OCS to the
Subscription request.
The Subscription is
required for obtaining the
A/V Edge Server URI
which is followed by the
notify message containing
the credentials).
ICE failure: The
Notify message
containing the A/V
Edge Server URI
was not received
Notify The Notify message
containing the A/V Edge
Server URI was not
received by the MCU.
ICE failure:
Received
Notification does not
contain URI.
Notify The notify message that
was sent from the A/V
Edge Server does not
contain the A/V Edge
server URI.
Verify the A/V Edge server is
configured in the OCS.
ICE failure: No
response from the
A/V Edge Server to
the MCU Service
Request
Service The MCU did not receive
a confirmation response
from the A/V Edge Server
to the Service request.
ICE failure:
Received Service
message does not
contain the
Credentials.
Service The Service message
response does not
contain the Credentials.