Polycom RMX 1500 Stereo Receiver User Manual


  Open as PDF
of 1010
 
Chapter 21-RealPresence Collaboration Server (RMX) Administration and Utilities
Polycom, Inc. 21-5
Table 21-2 RMX Time – Fields Properties
Field Description
GMT Date The date at Greenwich, UK.
Local Time The MCU’s local time settings, are calculated from the GMT Time and
the GMT Offset.
GMT Time The MCU’s current GMT Time settings.
Select the Up or Down arrows to alter the GMT Time on the MCU.
GMT Offset The time zone difference between Greenwich and the RMX’s physical
location in hours and minutes.
Select the Up or Down arrows to alter the GMT Offset time on the
MCU. To enter a negative offset either type a minus in the hour box or
use the down arrow and decrease the offset below zero.
Retrieve Client Time Click this button to automatically update the MCU’s GMT Date, Time
and Offset to match that of the workstation.
Use NTP Server Select this check box to synchronize the time with up to three NTP
servers. When selected, the manual GMT Date and GMT Time
setting options are disabled. The GMT Offset fields are still active.
To implement this mode an external connection to an NTP server
must be enabled.
Enter the IP addresses of the required NTP servers in order of
precedence.
The Status field indicates whether registration with the NTP Server
failed or succeeded.
Adjust Reservations
Time
(Button)
Use this button to adjust the start time of all the reservations in one
operation. For more information see "Adjusting the Start Times of all
Reservations” on page 9-16
After resetting the MCU a delay may occur when synchronizing with the external NTP server.