Polycom RMX 1500 Stereo Receiver User Manual


  Open as PDF
of 1010
 
Polycom RealPresence Collaboration Server (RMX) 1500/2000/4000 Administrator’s Guide
C-12 Polycom, Inc.
T120 Rate Not supported.
Always contains the value 0.
Table C-4 Event Fields for Event 2001 - CONFERENCE START CONTINUE 1
Field Description
Audio Tones Not supported.
Always contains the value 0.
Alert Tone Not supported.
Always contains the value 0.
Talk Hold Time The minimum time that a speaker has to speak to become the video source.
The value is in units of 0.01 seconds.
Currently the only value is 150, which indicates a talk hold time of 1.5
seconds.
Audio Mix Depth The maximum number of participants whose audio can be mixed.
Currently the only value is 5.
Operator
Conference
Not supported.
Always contains the value 0.
Video Protocol The video protocol.
Currently the only value is:
255 -
Auto
Meet Me Per
Conference
Indicates the Meet Me Per Conference setting.
Currently the only value is:
1 - The Meet Me Per Conference option is enabled, and dial-in participants
can join the conference by dialing the dial-in number.
Number of Network
Services
Not supported.
Always contains the value 0.
Chairperson
Password
The chairperson password for the conference.
An empty field “” means that no chairperson password was assigned to the
conference.
Chair Mode Not supported.
Always contains the value 0.
Cascade Mode The cascading mode.
Currently the only value is:
0 - None
Master Name Not supported.
This field remains empty.
Table C-3 Event Fields for Event 1 - CONFERENCE START (Continued)
Field Description