Polycom RealPresence Collaboration Server (RMX) 1500/2000/4000
22-18 Polycom, Inc.
3 To modify a flag value, double-click or select the flag and click the Edit Flag button.
4 In the New Value field, enter the flag’s new value.
5 Click OK to close the Update Flag dialog box.
6 Repeat steps 2–4 to modify additional flags.
7 Click OK to close the System Flags dialog box
Manually Adding and Deleting System Flags
To add a flag:
1 In the System Flags dialog box, click the New Flag ( ) button.
The New Flag dialog box is displayed.
2 In the New Flag field enter the flag name.
3 In the Value field enter the flag value.
USER_LOCKOUT_DURATIO
N_IN_MINUTES
Defines the duration of the Lockout of the user.
Value: 0 - 480
0 means permanent User Lockout until the administrator re-
enables the user within the system.
Default: 0
USER_LOCKOUT_WINDOW
_IN_MINUTES
Defines the time period during which the three consecutive
Login failures occur.
Value: 0 - 45000
0 means that three consecutive Login failures in any time
period will result in User Lockout.
Default: 60
Table 22-1 System Flags – MCMS_PARAMETERS (Continued)
Flag Description
For flag changes (including deletion) to take effect, reset the MCU. For more information see
"Resetting the RMX” on page 21-69.