![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/8b/18b1e1e7-4363-4706-bb94-6eba3a993996/18b1e1e7-4363-4706-bb94-6eba3a993996-bg199.png)
409
[Sysname-Serial2/0] fr interface-type dte
[Sysname-Serial2/0] timer hold 15
x25-template
Syntax x25-template name
undo x25-template name
View DLCI interface view
Parameter Name: Name of an X.25 template, a string of 1 to 30 characters.
Description Use the
x25-template command to apply an X.25 template to a VC.
Use the undo x25-template command to remove the X.25 template applied to
a VC.
Annex G implements X.25 over FR. You can configure X.25 parameters for an
X.25 over FR DLCI using the x25 template command and apply the template in
DLCI interface view.
Example # Apply the X.25 template named “vofr” to DLCI 100.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] fr dlci 100
[Sysname-fr-dlci-Serial2/0-100] x25-template vofr
x25 template
Syntax x25 template name
undo x25 template name
View System view
Parameter Name: Name of an X.25 template, a string of 1 to 30 characters.
Description Use the
x25 template command to create an X.25 template or enter X.25
template view.
Use the
undo x25 template command to remove an X.25 template.
As for the x25 template command, if the X.25 template identified by the name
argument already exists, this command leads you to X.25 template view.
X.25-/LAPB-related parameters are configured in X.25 template view.
Example # Create an X.25 template named “vofr”.