Roland MV-8000 Stereo Equalizer User Manual


 
64
Editing a sampled sound
Managing samples
To audition a sample
1.
Perform the steps described in
Accessing
the Sample Edit screen
(p. 60).
The SAMPLE EDIT screen will appear.
2.
Press (Sample List).
The saved samples will appear in the
SAMPLE
LIST popup
(p. 281).
3.
Select the sample you want to audition.
4.
Hold down (Preview).
The specified sample will play.
Deleting sample data
You can delete a sample at the same time that you delete a partial or audio phrase
assigned to a pad.
Deleting the sample along with the partial
1.
Press .
The INSTRUMENTS screen will appear.
2.
Use (up/down) to select the part of the partial that you want to delete.
The selected part number (the current part) will be highlighted.
3.
Hold down , and the VELOCITY PAD for the partial you
want to delete.
A confirmation message of “Delete Partial on Pad ##-##. Are You Sure?” will appear.
(##-## are the pad bank number and pad number.)
F button
Explanation
(No)
Cancels the operation (The partials and sample will remain).
(Assign Only)
Deletes the partial (the sample will remain).
(Yes)
Deletes the partials and sample used by that partial.
This will audition the
highlighted sample. To stop
auditioning, press [F4
(Preview)] once again.
INSTRU-
MENTS
You can't use the Undo
function to bring back a
deleted partial or sample.
ECS05_manual_e.book 64 ページ 2005年11月30日 水曜日 午前11時14分