System settings for the MV-8000
Testing the installed memory (Memory Diagnosis)
Here's how to perform a read/write test of the memory installed in the MV-8000.
1.
Access the SYSTEM INFORMATION screen as described in
Viewing the
system information
(p. 183).
2.
Press (DIMM Diag).
The display will ask “Save current project before”
While the test is being performed the display will indicate “Now Checking...” When
checking is completed, the result will be displayed.
3.
After noting the result of the test, press (Close).
Resetting the MV-8000's parameters to the factory
settings
Here's how to initialize all parameters of the MV-8000 to their factory settings.
1.
Access the SYSTEM INFORMATION screen as described in
Viewing the
system information
(p. 183).
2.
Press (Initialize).
The display will ask “Initialize system parameters. Are you sure?”
While initialization is being performed, the display will indicate “Now Processing...”
When the operation has been completed successfully, the display will indicate
“Completed.”
3.
After noting the result, press (Close).
F-button
Action
(No)
Executes the Memory Diagnosis
operation without saving the
current project.
(Yes)
Saves the current project, and
then executes the Memory Diag-
nosis operation.
Cancels the operation.
Display
Result
Memory Diagnosis: OK
The memory is functioning normally.
Memory Diagnosis: NG
A problem was found in the installed memory. Please
replace the memory as described in
Exchanging the
memory (removing and installing)
(p. 186).
F-button
Action
(No)
Cancels the operation.
(Yes)
Initializes the system parameters.
There is no way to recover
the data that has been
erased. (Unless, of course,
you have previously made
a backup of that data.)
Roland Corporation can
accept no responsibility for
any loss of data or any
damages you incur as a
result of such loss.
If this test produces a result of
NG, there is a problem with
the installed DIMM. Since data
cannot be read/written
correctly to this DIMM, it may
cause problems with the
operation of the MV-8000.
Please replace the DIMM (p.
186).
This operation initializes the
parameters that are saved in
system memory; it does not
erase the samples or library
data saved on the hard disk.