6. OPERATING THE VARIOUS LADDER MONITOR SCREENS
6 - 6
MELSEC
GOT
6) The Drive Selection Window is displayed. Select the drive
(applicable memory) with the following keys.
0
to
4
: Input the drive number.
0 (internal RAM)
1 - 4 (memory card)
AC
: Clear all input data on the drive.
: Define the input.
7) The file list of the selected drive is displayed. Select the ladder to
be read with the following keys.
: Move the cursor upward.
: Move the cursor downward.
Page
: Display the previous page.
Page
: Display the next page.
SEL.
: Move the cursor and touch the key to change select
(*)/cancel.
READ
: Start reading the selected ladder.
8) Contents and capacity of the reading process are displayed.
Touch
Break
to stop the reading process.
To read the ladder again, start from the beginning.
From the previous page
9) When the message "Completed" is displayed, reading is
completed. Change the screen with the following keys.
Exit
: Move to the screen when the ladder monitor is started.
Ladder
: Move to the ladder monitor screen.
Menu
: Start from setting window (2) for the network
No./station No.
POINT
When a keyword is registered at the PLC CPU, a key
window is displayed at the start of reading. Input the
keyword. (It does not have to be input if it is not registered.)
POINT
Once PLC reading is performed, operations for PLC reading
are not required from the next time onward.