1. OVERVIEW
1 - 10
MELSEC
GOT
1.3.3 Features of the system monitor function
Installing the screen monitor function operating system into the GOT built-in memory
using the drawing software enables monitoring and testing of the buffer memory for
the PLC CPU program and the special functions module. The features of the system
monitor function are shown below.
(1) Any desired device can be monitored, using 4 dedicated screens
The system monitor function provides an entry monitor, a batch monitor, and a
buffer memory monitor, enabling monitoring of any device, for complete flexibility
in any application.
Entry monitor
D 15 -2147483648 DW
D 10 -32767
X 001
M 25
Y 70
W 200 43
R 50 68378428 DW
D 300 30000
NETWK No. [ 0] STATION[FF]
DEVICE MONITOR TEST MENU FORM SET
Batch monitor
D 10 32767 D 18 -500
D 11 0 D 19 3234
D 12 0 D 20 0
D 13 -1 D 21 0
D 14 0 D 22 0
D 15 3 D 23 -32768
D 16 0 D 24 0
D 17 0 D 25 0
BATCH MONITOR TEST MENU FORM SET
NETWK No. [ 0] STATION[FF]
•
Up to 8 points for a PLC CPU device
registered by the user can be
monitored in one window (see
Section 9.2).
•
Up to 16 points subsequent to a
PLC CPU device specified by the
user can be monitored in one
window (see Section 9.3).
T/C monitor
T 0 PV 0 SV 0
[Production line A ]
T 1 PV 0 SV 0
[Production line B ]
T 2 PV 150 SV 150
[Production line C ]
T 3 PV 0 SV 0
[Production line D ]
TC MONITOR TEST MENU FORM SET
NETWK No. [ 0] STATION[FF]
Buffer memory monitor
BM MONITOR TEST
MENU FORM
SET
BM 1110 -32767 BM 1118 0
BM 1111 64 BM 1119 0
BM 1112 149 BM 1120 150
BM 1113 -1111 BM 1121 131
BM 1114 126 BM 1122 -32768
BM 1115 160 BM 1123 555
BM 1116 255 BM 1124 2368
BM 1117 1200 BM 1125 11000
NETWK No. [ 0] STATION[FF]
I/O NO[ 1]
•
Up to 8 points, including the current
value, set value, contact point, and
coil can be monitored in a window
subsequent to a PLC CPU timer
(T)/counter (C) specified by the user
(see Section 9.4).
•
Up to 16 points subsequent to the
buffer memory of a special function
module specified by the user can be
monitored in one window (see
Section 9.5).
•
With the GOT, the full screen can be divided into four windows and separate
monitoring carried out in all four windows simultaneously.
D 15 -2147483648 DW
D 10 -32767
X 001
M 25
Y 70
W 200 43
R 50 68378428 DW
D 300 30000
NETWK No.[ 0] STATION[FF]
DEVICE MONITOR TEST MENU FORM SET
BATCH MONITOR
NETWK No.[ 0] STATION[FF]
TEST MENU FORM SET
D 10 32767 D 18 -500
D 11 0 D 19 3234
D 12 0 D 20 0
D 13 -1 D 21 0
D 14 0 D 22 0
D 15 3 D 23 -32768
D 16 0 D 24 0
D 17 0 D 25 0
BM MONITOR
NETWK No.[ 0]
I/O NO[ 1]
STATION[FF]
TEST MENU FORM SET
BM 1110 -32767 BM 1118 0
BM 1111 64 BM 1119 0
BM 1112 149 BM 1120 150
BM 1113 -1111 BM 1121 131
BM 1114 126 BM 1122 -32768
BM 1115 160 BM 1123 555
BM 1116 255 BM 1124 2368
BM 1117 1200 BM 1125 11000
NETWK No.[ 0] STATION[FF]
TC MONITOR TEST MENU FORM SET
T 0 PV 0 SV 0
[Production line A ]
T 1 PV 0 SV 0
[Production line B ]
T 2 PV 150 SV 150
[Production line C ]
T 3 PV 0 SV 0
[Production line D ]