12. OPERATION OF EACH SPECIAL MODULE MONITOR SCREEN
12 - 90
MELSEC
GOT
*1 The display is based on the data in Bits 13 and 14 of the object buffer memory.
*2 The correspondence between the numeric value displayed in the "Operation Type"
column and the type of startup is shown below. The display is based on the data in
Bits 0 to 12 of the object buffer memory.
Data no. Type of startup Remarks
1 to 600 Startup with positioning operation
Indicates the data number at
the time of startup
7000 Startup with block positioning operation
8051 Startup with origin point return
8052 Startup with high-speed origin point return
8053 Startup with change in current value
8160 Startup with jogging operation
8161 Startup with manual pulser operation
Items with the "Re" prefix are displayed based on the data of Bit 15 of the object buffer
memory.