3. SPECIFICATIONS
3 - 11
MELSEC
GOT
3.5.4 List of key arrangement and key functions
Key arrangement and key functions of the list edit window are shown below.
List EDITOR
SHIFT
READ
WRITE
INSERT
DELETE
PARAM
OTHER
HELP
B
B
TO
C
INC
E
FROM
A
D
D
F
F
/
H
CALL
I
DEC
K
*
G
RET
J
MRD
L
>
N
<
O
=
Q
MOV
M
P
P
MPP
R
-
T
BCD
U
W
W
+
S
BIN
V
MPS
X
AND
D
OR
E
NOP
Y
LD
C
MC
F
END
Z
ANI
9
ORI
A
LDI
8
MCR
B
ANB
5
ORB
6
SET
4
PLS
7
SFT
1
CJ
2
RST
0
OUT
SET
( )
CLEAR
( )
SP
3
GO
List
EDITOR
SHIFT
READ
WRITE
INSERT
DELETE
PARAM
OTHER
HELP
B
B
TO
C
INC
E
FROM
A
D
D
F
F
/
H
CALL
I
DEC
K
*
G
RET
J
MRD
L
>
N
<
O
=
Q
MOV
M
P
P
MPP
R
-
T
BCD
U
W
W
+
S
BIN
V
MPS
X
AND
D
OR
E
NOP
Y
LD
C
MC
F
END
Z
ANI
9
ORI
A
LDI
8
MCR
B
ANB
5
ORB
6
SET
4
PLS
7
SFT
1
CJ
2
RST
0
OUT
SET
( )
CLEAR
( )
SP
3
GO
W
hen the A985/97*/960GOT is used
1) Control key
2) Mode key
(key for selection of mode)
1) Control key
5)Command key (upper character)
Device number/constant set key (lower character)
3) Help key
When the A95*GOT is used
4) Command key
(upper character)
Device key (lower character)
No. Name Key General description of function
SET
Key that declares start of step number input or automatic scroll.
Switch key that makes the lower character valid on each key with dual functions.
Whether upper or lower character is valid can be checked on the display.
SHIFT
Switch key that makes the upper character valid on each key with dual functions.
Whether upper or lower character is valid can be checked on the display.
If the Clear key is pressed when the system is not in the Parameter mode, Other mode or
Help function, the screen returns to the initial status of the mode selection.
(The input commands or device numbers except for the mode are cleared.)
This is used for repeating the procedure if incorrect keys are pressed.
In the Parameter mode, the process is cancelled. After restarting, continue the operation.
In the Other mode, the screen returns to the previous display.
CLEAR
When the Help function is used, the screen returns to the display at the input of the
HELP
key.
SP
Key that provides blank space at the command and at between device names.
( )
( )
,
Key that moves the cursor on the display (
,
) or determines scroll directions.*
1) Control key
GO
Press this key at the last of a series of key operations to execute the operation.
Check the details of key operations on the display before pressing this key.
2) Mode key
to
PARAM
OTHER
WRITE
READ
Key that selects each mode of the List editor function.
Switch the upper/lower character mode with the
SHIFT
key.
3) Help key
HELP
Key that selects the help function in the mode supporting the help function.
4) Command key
Advice key
to
END
Z
FROM
A
Key that inputs K/H at the input of command, device name and constant input.
Only when the valid key of upper/lower character needs to be switched, switching is
allowed with input of the
SHIFT
and
SET
keys.
5) Command key
Device
No./Constant
setting key
to
RST
0
MC
F
Key that inputs the command, device number and constant.
Only when the valid key of upper/lower character needs to be switched, switching is
allowed with input of the
SHIFT
and
SET
keys.