12. OPERATION OF EACH SPECIAL MODULE MONITOR SCREEN
12 - 94
MELSEC
GOT
12.23.11 Monitoring axis control data
1)
2)
3)
4)
5)
6)
7)
Buffer memory address
to reference (decimal)
No. Contents of display
Axis 1 Axis 2 Axis 3
1) The value for the current value change is displayed.
1154
1155
1204
1205
1254
1255
2) The speed change value is displayed.
1156
1157
1206
1207
1256
1257
3)
The override value in relation to the positioning speed is
displayed.
1159 1209 1259
4)
The ON/OFF status for the flag indicating whether step action is
effective is displayed; this flag confirms the actions of the
various positioning data in the step function.
1 : Step effective (step action is carried out)
0 : Step invalid (step action is not carried out)
1172 1222 1272
5)
This displays the module to be used for step action in operation
based on the step function.
1 : Step action in data number modules
0 : Step action in reduced-speed modules
1173 1223 1273
6)
The ON/OFF status of the skip command is displayed.
1 : Request for skip in progress
0 : Request for skip has been completed/No request
1175 1225 1275
7)
The display shows whether control based on an external startup
signal is effective or invalid.
1 : External startup effective
0 : External startup invalid
1171 1221 1271