12. OPERATION OF EACH SPECIAL MODULE MONITOR SCREEN
12 - 69
MELSEC
GOT
12.21.2 Zero return monitor
1)
2) 13) 14)
3) 4)
5)
6)
7)
8)
9)
10)
11)
12)
17)
16)
15)
15)
Buffer memory address
to reference (decimal)
No. Contents of display
X axis Y axis
1)
The ON/OFF status of the I/O signal corresponding to the PLC CPU is
displayed. The I/O signal is ON when displayed in a reverse display.
2) The set manual pulser run enabled/disabled status is displayed. 47 347
3) The data number during execution of current positioning is displayed. 48 348
4) The remaining pointer value is displayed. 39 339
5) The current value during execution of current positioning is displayed.
602
603
604
605
6) The change value of the current value is displayed.
41
42
341
342
7) The zero address set value is displayed.
7912
7913
7922
7923
8) The set value of the output speed is displayed. 600 601
9) The set value of the speed limit is displayed. 7874 7894
10) The change value of the speed change is displayed. 40 340
11) The set value of the zero return speed is displayed. 7914 7924
12) The set value of the zero return creep speed is displayed. 7915 7925
13) The set value of the M code is displayed. 0: M code not used 46 346
14) The error code is displayed when an error occurs. 45 345
15)
The zero return data is displayed.
b4b15 b0
Method where return is complete when stopper stops.
Zero return direction
Zero return method
7918 7928
16) The set value of the torque limit is displayed. 7917 7927
17) The set value of the dwell time is displayed. 7916 7926