12. OPERATION OF EACH SPECIAL MODULE MONITOR SCREEN
12 - 15
MELSEC
GOT
12.6 A1S62DA module monitor
12.6.1 Operation monitor
1)
4)
5)
6)
7)
13
)
12
)
11
)
5)
6)
7)
8)
9)
10)
8)
10)
9)
2) 3)
No. Contents of display
Buffer memory address
to reference (decimal)
1)
The specified enable/disable status for the analog output of each channel is
displayed.
0: Enable 1: Disable
0
2)
The channel 1 digital input value is displayed.
1
3)
The channel 2 digital input value is displayed.
2
4)
The ON/OFF status of the I/O signal corresponding to the PLC CPU is displayed. The
I/O signal is ON when displayed in a reverse display.
5)
The current input value, a value between -4000 to 4000 for the digital input value of
channels 1 and 2, is displayed in a graph as a percentage ranging from 0 to 100%.
6)
The current input value, a value between -8000 to 8000 for the digital input value of
channels 1 and 2, is displayed in a graph as a percentage ranging from 0 to 100%.
7)
The current input value, a value between -12000 to 12000 for the digital input value of
channels 1 and 2, is displayed in a graph as a percentage ranging from 0 to 100%.
8)
The current input value, a value between 0 to 4000 for the digital input value of
channels 1 and 2, is displayed in a graph as a percentage ranging from 0 to 100%.
9)
The current input value, a value between 0 to 8000 for the digital input value of
channels 1 and 2, is displayed in a graph as a percentage ranging from 0 to 100%.
10)
The current input value, a value between 0 to 12000 for the digital input value of
channels 1 and 2, is displayed in a graph as a percentage ranging from 0 to 100%.
1, 2
11)
When the channel 1 digital input value was set outside the allowable setting range, a
check code is displayed.
10
12)
When the channel 2 digital input value was set outside the allowable setting range, a
check code is displayed.
11
13)
The set resolution selection is displayed.
1: 1/4000 2: 1/8000 3: 1/12000
9