7. WIRING
7.1 Power Supply Wiring
7 - 3
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
PARTS NAME
5
UL, cUL
STANDARDS AND
EMC DIRECTIVE
6
INSTALLATION
7
WIRING
8
OPTION
Recommended terminal shape
Terminal screws should be tightened to between 0.5 to 0.8N·m. Terminal screws must be secured to prevent a loose
connection thus avoiding a malfunction.
Do not tighten the terminal screw with a torque exceeding the specified torque. Failure to do so may cause
equipment failures or malfunctions.
7.1.3 The cause of malfunctions related wiring/Remedy
Grounding of the GOT may cause electric potential difference and noise interference, which may result in GOT
malfunctions. These problems may be resolved by taking the following measures.
Wiring path of the GOT's ground cable and power line
Bundling the GOT's ground cable and power line together can cause interference noise, which may result in
malfunctions.
Keeping the GOT's ground cable and power line away from each other will help minimize noise interference.
Cable size
For power supply: 0.75mm
2
or more For grounding: 2mm
2
or more
Solderless terminal M3 solderless terminal (applicable solderless terminal: RAV1.25-3, V2-N3A, FV2-N3A)
Tightening torque 0.5 to 0.8N·m
6.2mm
or less
6.2mm
or less
3.2
3.2
When wiring one cable to
one terminal
When wiring two cables to
one terminal
Terminal
screw
Solderless
terminal
Terminal
screw
Solderless
terminal
FG
Power supply for power equipment
Good : Wiring the ground cable away from the
power cable
FG
Power supply for power equipment
Bad : Bundling the ground cable and