Agilent Technologies 35670-90066 Stereo System User Manual


 
Harmonic Distortion
Measurement Lower Limit Upper Limit
(dBfs)
Measured Value
(dBfs)
Pass/Fail
Two Ch, 12.25 kHz 2nd, Ch 1
80
Two Ch, 12.25 kHz 2nd, Ch 2
80
Four Ch, 12.25 kHz 2nd, Ch 1
80
Four Ch, 12.25 kHz 2nd, Ch 2
80
Four Ch, 12.25 kHz 2nd, Ch 3
80
Four Ch, 12.25 kHz 2nd, Ch 4
80
Two Ch, 8.167 kHz 3rd, Ch 1
80
Two Ch, 8.167 kHz 3rd, Ch 2
80
Four Ch, 8.167 kHz 3rd, Ch 1
80
Four Ch, 8.167 kHz 3rd, Ch 2
80
Four Ch, 8.167 kHz 3rd, Ch 3
80
Four Ch, 8.167 kHz 3rd, Ch 4
80
Two Ch, 6.125 kHz 4th, Ch 1
80
Two Ch, 6.125 kHz 4th, Ch 2
80
Four Ch, 6.125 kHz 4th, Ch 1
80
Four Ch, 6.125 kHz 4th, Ch 2
80
Four Ch, 6.125 kHz 4th, Ch 3
80
Four Ch, 6.125 kHz 4th, Ch 4
80
Two Ch, 4.9 kHz 5th, Ch 1
80
Two Ch, 4.9 kHz 5th, Ch 2
80
Four Ch, 4.9 kHz 5th, Ch 1
80
Four Ch, 4.9 kHz 5th, Ch 2
80
Four Ch, 4.9 kHz 5th, Ch 3
80
Four Ch, 4.9 kHz 5th, Ch 4
80
Serial Number:_______________________Report Number:____________________
Test Date:___/___/___
Agilent 35670A Verifying Specifications
Performance Test Record - Four Channel
15 of 20