Configuration and Use Manual 283
Series 3000 Menu Flowcharts
Relay Installation Series 3000 MenusDefaultsSpecifications – Model 3100 Relay Installation Series 3000 MenusDefaultsSpecifications – Model 3100 Relay Installation Series 3000 MenusDefaultsSpecifications – Model 3100 Relay Installation Series 3000 MenusDefaultsSpecifications – Model 3100
Figure F-8 Configuration menu
Management Menu
Configuration
InputsSystem
Enable
( Tag
( Time
( Date
( Alarm Severity
( Electronics Alarms
( Process Alarms
( Sensor Alarms
( Configuration Alarms
Frequency Input
( Flow Rate Units
( Scaling Method
( Frequency
(6)
( Flow
(6)
( Pulses/Unit
(6)
( Units/Pulse
(6)
( K-factor
Sensor Information
( Sensor Model No.
( Sensor Serial No.
( Sensor Material
( Sensor Flange
( Sensor Liner
Core Processor
( FCF
( FTG
( FFQ
( D1–4
( K1–4
( FD
( DT
( DTG
( DFQ1–DFQ2
( Temperature Slope
( Temperature Offset
( Mass Factor
( Density Factor
( Volume Factor
Discrete Inputs
( Start Zero
( Reset Mass Total
( Reset Volume Total
( Reset API Cor Vol Tot
(4)
( Reset ED Std Vol Tot
(5)
( Reset ED Net Mass Tot
(5)
( Reset All Totals
( Start/Stop All Totals
External Inputs
( Polling Variable 1–2
( Polling Control
( Polled Variable
( Pressure Compensation
(7)
( Pressure Units
(7)
( Flow Factor
(7)
( Density Factor
(7)
( Cal Pressure
(7)
( Ext Temp Compensation
(8)
Discrete Inputs
( Discrete Input 1–2
( Polarity
continued
Config Process Var
( Flow Variables
( Flow Damping
( Flow Direction
( Mass Units
( Mass Low Flow Cutoff
( Volume Flow Type
( Volume Units
(1)
( Vol Low Flow Cutoff
(1)
( Std Gas Volume Units
(2)
( Std Gas Volume Cutoff
(2)
( Std Gas Density
(2)
( Special Mass Units
( Special Volume Units
(1)
( Special Gas Std Units
(2)
( Density
( Density Units
( Density Damping
( Density Cutoff
( Slug Low Limit
( Slug High Limit
( Slug Duration
( Temperature
( Temperature Units
( Temperature Damping
Sensor Cal Data
( T-Series Setup
(3)
( Flow Cal
( D1–2
( K1–2
( FD
( Dens Temp Coeff
( Temp Cal Factor
( Temperature Slope
( Temperature Offset
( Mass Factor
( Density Factor
( Volume Factor
NoYes
(1) Liquid volume; displayed only if Volume Flow Type = Liquid.
(2) Gas standard volume; displayed only if Volume Flow Type = Gas Standard.
(3) T-Series option displayed only if transmitter is not connected to sensor. The parameter list displayed depends on the
sensor type.
(4) Displayed only if the petroleum measurement application is installed.
(5) Displayed only if the enhanced density application is installed.
(6) Options displayed depend on Scaling Method.
(7) Displayed only if Polled Variable = Pressure.
(8) Displayed only if Polled Variable = Temperature.