Emerson Series 3000 MVD Satellite Radio User Manual


 
146 Micro Motion
®
Series 3000 MVD Transmitters and Controllers
Operation Mode
Figure 17-3 Working with the View menu
17.5.1 Active alarm log
The platform performs self-diagnostics during operation. If the platform detects certain events or
conditions, an alarm message appears in the highlight bar at the top of the screen and an item is added
to the active alarm log.
The active alarm log lists:
All alarms that are active (the condition that caused the alarm is active)
All alarms that have not been acknowledged (even if the condition causing the alarm is no
longer active)
The alarm will be listed in the active alarm log and displayed in the highlight bar until the alarm has
been acknowledged.
The active alarm log is organized in either of two ways:
If accessed via the View menu, as shown in Figure 17-2, only alarm categories containing
active or unacknowledged alarms are listed. Alarm categories are listed in order of priority
(Electronics, Sensor, Process, Configuration). To view individual alarms, place the cursor on
an alarm category and press
HELP.
If accessed via the Maintenance menu, individual alarms are listed in numerical order by alarm
number (alarm numbers are documented in Section 22.7).
For information about acknowledging alarms or responding to alarm messages, see Section 22.6.
ALARMS
VIEW MENU
Active Alarm Log
Process Monitoring
Preset Selections
Batch Inventory
Process Totalizers
Diagnostic Monitor
Density Curves
LCD Options
Applications List
SEL HELP EXIT
SEL Select highlighted option
CHG Make a change to the
highlighted option
SAVE Save a change
STOP Pause counting of all
totalizers except batch
START Resume counting of all
totalizers except batch
RESET Reset totalizer
PRINT Print a ticket
Move cursor upward
Move cursor downward
EXIT
SELECT
HELP Show a help screen
RESET Reset total
EXIT Return to operation screen