160 Micro Motion
®
Series 3000 MVD Transmitters and Controllers
Operation Mode – Custody Transfer
Table 19-1 Series 3000 behavior and available functions
Custody transfer (NTEP)
Custody transfer (OIML) and
custody transfer (OIML/batch)
Function Secured Unsecured Secured Unsecured
Batch processing
Batch reset Y Y Y Y
Batch start, stop, resume Y Y Y Y
Batch BOL number
changed manually
NYNY
Different batch preset
selected
YYYY
Transfer BOL number changed
manually
N/A N/A N Y
Time of day Can be changed by
one hour in either
direction. Cannot be
changed in the
same direction
twice consecutively.
Y Can be changed by
one hour in either
direction. Cannot be
changed in the
same direction
twice consecutively.
Y
External pressure and
temperature data
Updated via polling Y Y Y Y
Updated by Modbus or
HART host
NYNY
Calibration
Zero NYNY
Density N Y N Y
Temperature N Y N Y
Meter verification
Original version N Y N Y
Smart Meter Verification
• Outputs set to Continue
Measuring
YYYY
• Outputs set to Fault Y Y Y Y
• Outputs set to Hold Last
Value
NYNY