Emerson Series 3000 MVD Satellite Radio User Manual


 
Configuration and Use Manual 259
Relay Installation Series 3000 MenusDefaultsSpecifications – Model 3100
Appendix C
Specifications – Model 3100
C.1 Overview
The Model 3100 accessory features relay packs for interfacing with high-energy solenoids, pump
starters, or other devices.
C.2 Relay packs
The Model 3100 contains three relays with the following characteristics:
Solid state, SPST
Rated at 24–250 VAC, 40 mA–5 A; or 0–70 VDC, 5 A
Energized by discrete outputs
C.3 Hazardous area classifications
C.3.1 ATEX
Zone 2, complying with ATEX Directive (94/9/EC) for Group II, Category 3G, according to
CENELEC standard prEN 50021:1998 and marked as:
EEx n V II T4
KEMA 97 ATEX 4940 X
Ambient temperature –20 to +60 °C (–4 to +140 °F)
C.3.2 UL and CSA
Class I, Division 2, Groups A, B, C, and D