Emerson Series 3000 MVD Satellite Radio User Manual


 
Configuration and Use Manual 257
Specifications – Model 3350 and Model 3700
Diagnostics and Troubleshooting Specifications – Model 3350/3700Specifications – Model 3300/3500Measurement Performance Diagnostics and Troubleshooting Specifications – Model 3350/3700Specifications – Model 3300/3500Measurement Performance Diagnostics and Troubleshooting Specifications – Model 3350/3700Specifications – Model 3300/3500Measurement Performance Diagnostics and Troubleshooting Specifications – Model 3350/3700Specifications – Model 3300/3500Measurement Performance
B.7 Power supply options
85 to 265 VAC
50/60 Hz, 30 VA
0.33 A max at 85 VAC; 0.15 A max at 265 VAC
IEC 127-3/4 fuse, 0.63 A time-delay
Complies with “low-voltage directive” 2006/95/EC per IEC 61010-1
Installation (Overvoltage) Category II, Pollution Degree 2
18 to 30 VDC
18 watts typical, 25 watts maximum
IEC 127-3/4 fuse; 1.6 A time-delay
B.8 Environmental limits
Ambient temperature:
- Operating: –4 to +140 °F (–20 to +60 °C)
- Storage: –40 to +158 °F (–40 to +70 °C)
Some darkening of display may occur above 131 °F (55 °C). Display responsiveness decreases
below –4 °F (–20 °C).
Humidity: 5 to 95% relative humidity, non-condensing at 140 °F (60 °C)
Vibration: Meets IEC 68.2.6, endurance sweep, 5 to 2000 Hz, 50 sweep cycles at 1.0 g
B.9 Environmental effects
EMI effects
Meets EMC directive 89/336/EEC per EN 61326 Industrial
Conforms to NAMUR NE21 (June 1997)
Ambient temperature effect
On analog outputs ± 0.005% of span per °C
B.10 Hazardous area classifications
B.10.1 ATEX
Zone 1, complying with ATEX Directive (94/9/EC) for group II category 2G and marked as
EEx de [ib] IIB/IIC T4.
B.10.2 UL and CSA
Class I, Div. 2, Groups A, B, C, and D. Provides nonincendive sensor outputs for use in Class I, Div.
2, Groups A, B, C, D, or intrinsically safe sensor outputs for use in Class I, Div. 1, Groups C and D;
Class II, Div. 1, Groups E, F, and G.