368 Chapter 5
Language Reference
STATus Subsystem
Factory Preset
and *RST: 0
Range: 0 to 32767
Questionable Event Query
:STATus:QUEStionable[:EVENt]?
This query returns the decimal value of the sum of the bits in the
Questionable Event register.
NOTE The register requires that the associated PTR or NTR filters be set
before a condition register bit can set a bit in the event register.
The data in this register is latched until it is queried. Once queried, the
register is cleared.
Key Type: There is no equivalent front panel key.
Questionable Negative Transition
:STATus:QUEStionable:NTRansition <number>
:STATus:QUEStionable:NTRansition?
This command determines what bits in the Questionable Condition
register will set the corresponding bit in the Questionable Event
register when the condition register bit has a negative transition (1 to
0). The variable <number> is the sum of the decimal values of the bits
that you want to enable.
Key Type: There is no equivalent front panel key.
Factory Preset
and *RST: 0
Range: 0 to 32767
Questionable Positive Transition
:STATus:QUEStionable:PTRansition <number>
:STATus:QUEStionable:PTRansition?
This command determines what bits in the Questionable Condition
register will set the corresponding bit in the Questionable Event
register when the condition register bit has a positive transition (0 to 1).
The variable <number> is the sum of the decimal values of the bits that
you want to enable.