Agilent Technologies E4406A VSA Satellite Radio User Manual


 
Chapter 5 335
Language Reference
SENSe Subsystem
Remarks: You must be in the Basic, cdma2000, W-CDMA (3GPP),
or W-CDMA (Trial & Arib) mode to use this command.
Use INSTrument:SELect to set the mode.
Power vs. Time Measurement
Commands for querying the power versus time measurement results
and for setting to the default values are found in the MEASure Group
of Commands on page 255. The equivalent front panel keys for the
parameters described in the following commands, are found under the
Meas Setup key, after the Power vs Time measurement has been selected
from the
MEASURE key menu.
Power vs. TimeNumber of Bursts Averaged
[:SENSe]:PVTime:AVERage:COUNt <integer>
[:SENSe]:PVTime:AVERage:COUNt?
Set the number of bursts that will be averaged. After the specified
number of bursts (average counts), the averaging mode (terminal
control) setting determines the averaging action.
Factory Preset
and *RST: 15
Range: 1 to 10,000
Remarks: You must be in the EDGE(w/GSM), GSM or Service
mode to use this command. Use INSTrument:SELect to
set the mode.
Power vs. TimeAveraging State
[:SENSe]:PVTime:AVERage[:STATe] OFF|ON|0|1
[:SENSe]:PVTime:AVERage[:STATe]?
Turn averaging on or off.
Factory Preset
and *RST: OFF
Remarks: You must be in the EDGE(w/GSM), GSM or Service
mode to use this command. Use INSTrument:SELect to
set the mode.