Agilent Technologies E4406A VSA Satellite Radio User Manual


 
Chapter 5 295
Language Reference
SENSe Subsystem
Factory Preset
and *RST:
Remarks: You must be in the NADC, cdmaOne, or PDC mode to
use this command. Use INSTrument:SELect to set the
mode.
Adjacent Channel PowerOffset Frequency Test Mode
[:SENSe]:ACP:LIST:TEST ABSolute|AND|RELative|OR,
ABSolute|AND|RELative|OR, ABSolute|AND|RELative|OR,
ABSolute|AND|RELative|OR, ABSolute|AND|RELative|OR
[:SENSe]:ACP:LIST:TEST?
Define the type of testing to be done for the five custom offset
frequencies. You can turn off (not use) specific offsets with the
SENS:ACP:LIST:STATe command.
Factory Preset
and *RST: RELative, RELative, OR, AND, AND for NADC, PDC
mode
Remarks: You must be in the NADC, cdmaOne, or PDC mode to
use this command. Use INSTrument:SELect to set the
mode.
Adjacent Channel PowerAbsolute Amplitude Limits
iDEN mode
[:SENSe]:ACP:OFFSet:ABSolute <power>
[:SENSe]:ACP:OFFSet:ABSolute?
Basic, cdmaOne
[:SENSe]:ACP:OFFSet:LIST:ABSolute
<power>,<power>,<power>,<power>,<power>
[:SENSe]:ACP:OFFSet:LIST:ABSolute?
cdma2000, W-CDMA (3GPP) mode
[:SENSe]:ACP:OFFSet[n]:LIST:ABSolute
<power>,<power>,<power>,<power>,<power>
Mode Offset A Offset B Offset C Offset D Offset E
NADC ON ON ON OFF OFF
PDC ON ON OFF OFF OFF