Agilent Technologies 62A Stereo System User Manual


 
Agilent N5161A/62A/81A/82A/83A MXG Signal Generators User’s Guide 285
Custom Digital Modulation (Option 431)
Differential Encoding
Editing the Differential State Map
1. Press 1 > Enter.
This encodes the first symbol by adding a symbol table offset of 1. The symbol rotates forward
through the state map by 1 value when a data value of 0 is modulated.
2. Press +/– > 1 > Enter.
This encodes the second symbol by adding a symbol table offset of 1. The symbol rotates
backward through the state map by 1 value when a data value of 1 is modulated.
NOTE At this point, the modulation has one bit per symbol. For the first two data values (00000000
and 00000001) only the last bits (the 0 and the 1, respectively) are significant.
3. Press 2 > Enter.
This encodes the third symbol by adding a symbol table offset of 2. The symbol rotates forward
through the state map by 2 values when a data value of 10 is modulated.
4. Press 0 > Enter.
This encodes the fourth symbol by adding a symbol table offset of 0. The symbol does not rotate
through the state map when a data value of 11 is modulated.
NOTE At this point, the modulation has two bits per symbol. For the data values 00000000,
00000001, 00000010, 00000011, the symbol values are 00, 01, 10, and 11 respectively.
Applying Custom Differential Encoding
Press Return > Differential Encoding Off On.
This applies the custom differential encoding to a user–defined modulation.
NOTE Notice that (UNSTORED) appears next to Differential State Map on the signal generator’s
display. Differential state maps are associated with the user–defined modulation for which
they were created.
In order to save a custom differential state map, you must store the user–defined modulation
for which it was designed. Otherwise the symbol table offset data is purged when you press
the Confirm Exit From Table Without Saving softkey when exiting from the I/Q or FSK table editor.