6/08 ST 3000 Release 300 and SFC Model STS103 User’s Manual 121
6.12 Configuring Smart Meter Using Pushbuttons, Continued
Button Pushing
Summary
Figure 37 shows button pushing summary for the smart meter display to
set the lower and upper display limits.
Figure 37 Button Pushing Summary for Setting Lower and Upper Display Limits.
Is
EUF in
LINEAR
or
SQUARE ROOT
mode?
Is
EUD or EUE
selected?
YES
NO
LINEAR
Mode
SQUARE ROOT
Mode
Set active digit value 0 to 9
Lower
Value
Upper
Value
Set magnitude range: 19.99, 199.9, 1999,
19.99K, 199.9K, 1999K, 19990K
If display limit was previously set, KNOWN VALUE indicator lights
and set value flashes in display.(Note that lower display limit is
fixed at zero (0.00) for units in SQUARE ROOT mode.)
Lower
Value
Upper
Value
Set 1 digit to BLANK Set 1 digit to 1
Set sign segment
BLANK for positive
values
Set sign segment
to minus sign (-) for
negative values
Are both lower and
upper display limit
values set?
Yes
No
Is "1" digit active?
Yes
No
Set Lower
Range Value
Set Upper
Range Value
Lower
Value
Upper
Value
Lower
Value
Upper
Value
Lower
Value
Upper
Value
Lower
Value
Upper
Value
End
A