6/08 ST 3000 Release 300 and SFC Model STS103 User’s Manual 91
6.9 Selecting Output Signal Mode (DE Mode Only)
DE configuration
parameters
You must configure these additional parameters for a transmitter in the
DE mode of operation.
• Mode of Output Signal Indication
• Message Format
This section and the next section cover how to configure these
parameters individually. However, once you enter the DE configuration
function, you can access all DE configuration parameters serially
without exiting the function. Just use the [s NEXT ] and [t PREV] keys to
step through the parameter selections.
Background
You can select the output signal mode for digital transmission to be one
of these three modes as described in Table 20.
• Single Range
• Dual Range (STDC)
• Single Range W/SV
Procedure
The procedure in Table 28 outlines the steps for selecting a Single
Range W/SV mode for example purposes only.
Table 28 Selecting Mode of Output Signal Indication
Step Press Key Read Display or Action Description
1
^
SHIFT
DE CONF
MENU
ITEM
I
LIN DP
FT–SHI
TØ11P3
ORK NGCW .F.S.I
PTDE 3011OCNF
eRngnliSea
PTDE 3011OCNF
g
Initiate shift key selection.
Calls up DE CONFIG menu. Output
signal mode selection appears.
2
DE CONF
MENU
ITEM
I
DE CONF
MENU
ITEM
I
eRgnliSn
PTDE 3011OCNF
g
w/SV
RngauDea
PTDE 3011OCNF
l(
STDC
)
Calls up next output signal mode
selection.
Repeatedly press [
MENU ITEM] key to
step through all output signal mode
selections listed in Table 20 in
sequence. Stop when “Single Range
W/SV” mode is on display.
Continued on next page