June 1999
Maintenance Object Repair Procedures
9-290AUX-TRK (Auxiliary Trunk)
9
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1 with Aux Data 57481 indicates a port fault. Use an empty port
if one is available until the circuit pack can be replaced.
b. Error Type 1 or 769 with Aux Data 57482 indicates a fault on signaling
lead, which is an off-board error. This error should only occur with
loudspeaker paging. If the trunk is being used for another application,
check that the administration is correct. Otherwise, check the wiring to the
external equipment connected to the Auxiliary Trunk and check the
external equipment.
c. This is a software audit error that does not indicate any hardware
malfunction. Run Short Test Sequence and investigate associated errors.
d. Indicates the circuit pack has been removed or has been insane for more
than 11-minutes. To clear the error, reseat or replace the circuit pack.
Table 9-131. Auxiliary Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1(a) 57481 None
1(b) 57782
15(c) Any Audit Update Test (#36)
18 0 busyout port UUCSSpp WARNING OFF release port UUCSSpp
130(d) None WARNING ON test trunk <grp>/<mbr> sh
769(b) 57482 None
257 Hybrid/Conference MIN/WRN
2
2. Major or Minor alarms may be downgraded to Warning alarms based on the values used in the set
options command.
ON test port UUCSSpp l r 3
Circuit Test (#33)
513 NPE Crosstalk Test (#6) MIN/WRN
2
ON test port UUCSSpp l r 3
1025 Diagnostic Test
Auxiliary Trunk Test
(#114)
WARNING ON test port UUCSSpp sh r 3