![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg8b8.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1548SVC-SLOT (Service Slot)
9
SVC-SLOT (Service Slot)
The Service Slot maintenance object detects the insertion of an invalid circuit
pack a dedicated SERVICE slot. The SERVICE slot is the leftmost slot in the
J58890BB Port Carrier, and is identified as slot location "00" in all commands,
field entries, and displays on the management terminal.
Since this slot does not provide tip and ring connectivity to the wall field, only the
following circuit packs are allowed:
■ TN744 Call Classifier
■ TN750 Integrated Announcement
■ TN771 Maintenance/Test
■ TN725 Speech Synthesizer
■ TN433 Speech Synthesizer
■ TN457 Speech Synthesizer
■ TN748 Tone Detector
■ TN420 Tone Detector
■ TN755 Neon Power Unit
A MINOR alarm is generated against the Service Slot maintenance object when a
circuit pack with a type other than that listed above is inserted in a SERVICE slot.
The Service Slot maintenance object name is used instead of the maintenance
object name for the illegal circuit pack to prevent any attempt to assign a port to
an illegal circuit pack physically inserted in the SERVICE slot.
MO Name (in
Alarm Log) Alarm Level Initial Command to Run Full Name of MO
SVC-SLOT MINOR none Service Slot