9-1269PKT-INT (Packet Interface Circuit Pack)
9
since the number of bad translations RAM locations indicates bad locations that
cannot be used. For a Packet Interface Circuit Pack on the active SPE,
information about the number of bad Translation location is sent to maintenance
software as an in-line error from the circuit pack so it is not necessary to read a
counter location.
Table 9-501. TEST #887 Read and Clear Board Counters
Error
Code
Tes t
Result Description/ Recommendation
1006
1137
ABORT Packet Interface circuit pack is in the out-of-service state so normal
maintenance tests will not run on that circuit pack.
1. Request a Packet Interface circuit pack reset using the reset
packet-interface CS command. Refer to the Packet Interface Reset Test
(#889) maintenance documentation for repair procedures.
1338 ABORT The test is not allowed to run since a planned SPE interchange is in progress. A
planned interchange may be caused by 24 hour scheduled testing. During this
time the terminal will be held out of service but it should recover automatically
after 3 minutes.
1. Wait 3 minutes and retry the command.
1339 ABORT The test could not run on the standby Packet Interface circuit pack because the
standby SPE is unavailable.
1. Refer to the STBY-SPE maintenance documentation for information on why
a standby SPE may be unavailable and what repair actions should be
taken. The status spe screen should indicate that handshake is down. This
may be caused by a variety of reasons such as the setting the
SPE-SELECT switches on the DUPINT circuit packs to the position of the
active SPE, a failure of the DUPINT circuit pack, or loss of power on the
standby SPE, The
SPE Selected field
on the status spe screen will display
spe a
or
spe b
if the SPE-SELECT switches are in the a or b position,
respectively.
1347 ABORT The test could not run because refresh of the standby SPE’s memory is not
complete.
1. Enter status spe and verify that refresh is not complete. Wait until the
status screen indicates that refresh is complete and try the command
again. The status screen should indicate that shadowing is on. If some
event such as a major alarm on a Packet Interface circuit pack on the
standby SPE causes shadowing to turn off, refresh cannot complete and
abort code 1350 will be returned when the test packet-interface command
is entered.
Continued on next page