A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1267PKT-INT (Packet Interface Circuit Pack)
9
1338 ABORT The test is not allowed to run since a planned SPE interchange is in progress.
A planned interchange may be caused by 24 hour scheduled testing. During
this time the terminal will be held out of service but it should recover
automatically after 3 minutes.
1. Wait 3 minutes and retry the command.
1373 ABORT Could not establish the link loop around link to run this test.
1. Retry the command at 1-minute intervals, a maximum of 3 times.
2060 ABORT Packet link bus went down during maintenance looparound test.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
2. If there are errors associated with the Packet Bus, refer to the
maintenance information associated with the Packet Bus.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, a maximum of 5 times.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals, a maximum of 5 times.
NO
BOARD
The Packet Interface circuit pack is administered but it is not detected as
being physically present.
1. If the Packet Interface circuit pack is present, replace it.
2. If the Packet Interface circuit pack is not physically present, use the
display system-parameters maintenance command to check if the
Packet Interface circuit pack is administered as being present. If it is
administered, use the change system-parameters maintenance
command to change the Packet Interface circuit packs administered to be
those actually present.
Table 9-500. TEST #886 Maintenance Looparound Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page