A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Management Terminal
3-24Connecting the MT
3
Connecting the MT
The management terminal can be connected to the system in the following ways:
SYSAM-LCL Port
The management terminal can be connected directly to the SYSAM-LCL
port of the TN1648 System Access and Maintenance (SYSAM) circuit
pack in the PPN control carrier (or SPE). Two RS-232 connectors are
located on the rear panel of the PPN control carrier beneath the label
TERMINAL. To access the maintenance user interface running on the
Table 3-4. Command Permissions Form Entries — Administer Trunks
Object
Action
Add Change Display Duplicate Remove
aar analysis X
aar digit-conversion X
access-endpoint X X X X
announcements X
ars analysis X
ars digit-conversion X
ars toll X
digit-absorption X
meas-selection route-pattern X
meas-selection trunk-group X
meas-selection wideband-trunk-grp X
modem-pool X X X
personal-CO-line X X X
pri-endpoint X X X X
remote-access X X
rhnpa X
route-pattern X
time-of-day X
toll X
trunk-group X X X