A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
LED Interpretation
7-2Attendant Console LEDs
7
button associated with the lighted alarm lamp. If the lamp is turned off, and the
alarm has not been resolved by the time maintenance reschedules testing, the
green status LED will resume its steady state. The following alarms are
displayed:
Attendant Console LEDs
The console has two red LEDs, labeled “ALM” and “ACK.” The ALM LED lights
steadily when there is a Major or Minor alarm at the switch cabinet. The ACK LED
lights steadily if the alarm has been successfully reported to INADS. If the system
is unable to report the alarm to INADS, the LED flashes; this signals the attendant
to call INADS and report the alarm.
ac-alarm Administered Connection Alarm: a locally administered
connection (ADM-CONN) has a Major, Minor, or Warning
alarm active.
pr-awu-alm Auto Wakeup Journal Printer Alarm: the automatic wakeup
journal printer has a Major, Minor, or Warning alarm active.
ds1-alarm DS1 Facility Alarm: a DS1-BD has an off-board Major, Minor,
or Warning alarm active.
trk-ac-alm Facility Access Alarm: The facility access trunk test feature
is activated.
major-alrm Major Alarm: The system has logged a Major Alarm.
mj/mn-alrm Major/Minor Alarm: The system has logged a Major or Minor
Alarm.
pr-pms-alm PMS Printer: The Property Management System printer has
a Major, Minor, or Warning alarm active.
rs-alert Reset-Alert:
reset system 2
or
3
has been performed.
cdr1-alrm Call Detail Recording Alarm: The Primary CDR Link has a
Major, Minor, or Warning alarm active.
cdr2-alrm Call Detail Recording Alarm: The Secondary Link has a
Major, Minor, or Warning alarm active.
pr-sys-alm System Printer Alarm: The System Printer (SYS-PRNT) has a
Major, Minor, or Warning alarm active.
pms-alarm The Property Management System has a Major, Minor or
Warning alarm active.