DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-758EMG-XFER (Emergency Transfer)
9
System Technician-Demanded Tests: Descriptions
and Error Codes (Single-Carrier)
Always investigate tests in the order presented in the following table. By clearing
error codes associated with the
Battery & Battery Charger Query Test,
for
example, you may also clear errors generated from other tests in the testing
sequence. For example, you may also clear errors generated from other tests in
the testing sequence.
Notes:
a. Refer to “DC-POWER” for a description of this test.
b. Refer to ‘‘EXT-DEV ADMIN? Y (External Device Alarm)’’
for a description of
this test.
c. Refer to ‘‘RING-GEN’’
for a description of this test.
NOTE:
These tests only show up in the test sequence if there is a TN768
Tone-Clock Board in the port network being tested.
Emergency Transfer Query Test (#124)
The Emergency Transfer Query Test queries the hardware for the state of the
Emergency Transfer switch (or switches in a duplicated SPE system) and reports
the result. If the position of the switch in a single SPE cabinet or EPN cabinet, or
switches in a duplicated SPE cabinet, is such that the system software can
control Emergency Transfer (auto), then the test passes. If the position of the
switch or switches is such that the system software cannot control Emergency
Transfer (manual “on” or manual “off”), then the test fails. In the PPN the SYSAM
controls Emergency Transfer, and in the EPN, the EPN Maintenance circuit pack
controls Emergency Transfer
Single-Carrier System
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
Power Query Test (#79) (a) X X ND
Emergency Transfer Query Test (#124) X X ND
External Alarm Lead Query Test (#120) (b) X X ND
Analog Ring Generator Initialization Test (#117) (c) X X ND
Analog Ring Generator Query Test (#118) (c) X X ND