DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1223PGATE-PT (Packet Gateway Port)
9
automatically loops back the signal at the port as shown in the the figure below.
Failure of this test indicates the existence of a fault in the port hardware on the
circuit pack.
Figure 9-76. Packet Gateway Port Local Loop-Around Test
This test aborts if calls are using the port or if the X.25 Access Link associated
with the port is connected. To avoid this, first enter
busyout data-module
extension or
busyout port
UUCSSpp or
busyout link
link#, which will cause all
calls and links using the port to be torn down.
Table 9-488. TEST #610 Packet Gateway Port Local Loop-Around Test
Error
Code
Tes t
Result Description/ Recommendation
1000 ABORT The X.25 Access Link is connected or the port is in use for a call. Execute
status packet-gateway-port UUCSSpp to determine when the port is
available for testing.
1. Retry the command when the port is idle. The port may be forced to the
idle state by executing a busyout port UUCSSpp command. This
command is destructive causing all calls and links associated with the port
to be torn down.
2000 ABORT Response to the test was not received from the Packet Gateway circuit pack
within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the other
ports on the board are not in use (Yellow LED is off). Reset the circuit pack
by issuing the busyout board UUCSS and the reset board UUCSS
commands.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals a maximum of 3 times.
Continued on next page
Data
Set
Data
Set
Port
TN566
Packet
Gateway
RS423 Transmission Facility