![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg1a3.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-108display system-parameters maintenance
8
Scheduled Maintenance
A series of maintenance tests and operations runs automatically every day
according to the schedule and settings specified in the following fields.
CPE Alarm
Activation
Level
Indicates the minimum level (Major, Minor or Warning) at which the
Customer-Provided Equipment (CPE) alarm is activated. If the
level is “none,” the CPE does is not activated for any alarm. (none)
NOTE:
The CPE alarm is always activated when the switch goes into
Emergency Transfer, regardless of the CPE Alarm Activation
Level setting.
Start Time
The hour and minute in 24-hour notation at which daily scheduled
maintenance will begin running. (22:00)
Stop Time
The hour and minute when scheduled daily maintenance will stop
running. If any daily maintenance operations are not completed
by this time, the system will note where in the sequence it
stopped and perform those operations during the next scheduled
daily maintenance.
Daily
Maintenance
This display-only field simply represents the series of tests that
are always run by maintenance software as part of daily
maintenance.
Save
Translation
This field indicates on which days translation data in memory will
automatically be saved to the Mass Storage System disk and/or
tape devices during scheduled maintenance. The save operation
is first made to disk, followed by a disk backup to tape. On
systems with duplicated SPEs, translation data is saved on both
SPEs. Valid entries are
daily
, days of the week, or
no
. “No”
specifies that no automatic saves are to be executed. (daily)
Control Channel
Interchange
Each port network has a pair of TDM busses called A and B,
each of which has a set of time slots dedicated to use by the
control channel. At any one time, the control channel in each PN
is carried on only one of the two busses. This field indicates on
which days the control channel in each port network will be
switched from one of the paired TDM busses to the other. Valid
entries are daily, days of the week, or no. “No” specifies that no
interchange be executed. (no)