![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg57e.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-722DUP-CHL (Duplication Interface)
9
Status Register Comparison Test (#980)
The Status Register Comparison Test compares active Duplication Interface
circuit pack remote status with standby Duplication Interface circuit pack local
status.
54 FAIL The attempt to turn on memory shadowing in this DUPINT circuit pack could not
be verified in the DUPINT hardware status register.
1. Replace Duplication Interface components starting with the standby
Duplication Interface circuit pack. Use SPE Duplication Channel
Component Replacement procedures at the end of this DUP-CHL section.
PASS The test was able to successfully shadow, within shadowed address space,
writes in the active SPE into the standby SPE memory.
Table 9-280. TEST #980 Status Register Comparison Test
Error
Code
Tes t
Result Description/ Recommendation
1321 ABORT The faceplate switches on the Duplication Interface circuit packs are not set to
auto.
1. If the switches are locked because you are using a replacement procedure,
continue with this procedure to the step that directs you to unlock the active
SPE by moving both switches to auto. The next step using the test
duplication-interface long clear should not abort with this error code.
2. If the switches are locked and a replacement procedure is not being used,
start with step 6 of the SPE Duplication Channel Component Replacement
procedure for the standby Duplication Interface Circuit pack at the end of
this DUP-CHL section to avoid an undesired interchange when unlocking
the active SPE.
3. If this same abort is received with both switches in auto, Replace
Duplication Interface components starting with the standby Duplication
Interface circuit pack. Use SPE Duplication Channel Component
Replacement procedures at the end of this DUP-CHL section. In addition to
looking for failures, also check for the absence of this 1321 abort code
when testing after the procedure directs setting the switches to auto after a
component replacement.
Continued on next page
Table 9-279. TEST #876 Memory Shadowing Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page