A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-112display system-parameters maintenance
8
RTS/CTS
Enabled
This field will inform the modem that communication with the data
source UART will be driven with RTS/CTS flow control. This field is 6
characters long and is case in-sensitive. (&H1)
Asynchronous
Data Mode
This field will configure the modem as an asynchronous
communications device. This field is 8 characters long and is case
in-sensitive. ( )
DTE Auto-Data
Speed
This option will adjust the speed of the data source (DTE) UART to
the outgoing (modem-to-modem) data rate. So, at maximum this
speed would be 9600 baud. This field is 6 characters long and is
case in-sensitive.
Note that this field sets the link speed between the switch and the
modem. It does not set the speed of the modem. It is not desirable
to have the serial data fill the modem buffer faster than the outgoing
data rate especially because data compression is disabled. ( )
Disable Data
Compression
This field will turn off the default data compression algorithms that
are in use by most consumer modems. This field is 6 characters
long and is case in-sensitive. (&K0)
Enable Error
Control
This field will turn on the V.42 LAPM and MNP error control
protocols, if available on the modem. This field is 6 characters long
and is case in-sensitive.
This V.42/MNP/Buffer mode first attempts to negotiate V.42 error
control with the remote modem. If this fails, then the modem
transitions to MNP, and if this fails then no error control is used. ( )
Misc. Init.
Param
This field supports any initialization parameters that are not already
specified. The AT commands specified in this free-form field will be
always the last initialization parameters to be sent to the external
modem. This field is 20 characters long and is case in-sensitive. ( )
Auto-Answer
Ring Count
This field controls the number of rings required before the modem
automatically answers an incoming call, if and only if the switch
doesn’t answer first. (If the switch is healthy, it answers an
incoming within the first few rings.) This field is 6 characters long
and is case insensitive. Typically, the maximum permissible value
for this register is 255. The values 1-255 denote the number of
incoming ring cycles. (S0=10)
NOTE:
The number of rings is optimally set above 5, and if at all
possible, keep the default of S0=10.
Dial Type This field controls the type of inter-register signaling to be used
between the modem and the Central Office. Use “T” for tone dialing
and “P” for pulse dialing. The field length is be 3 characters long
and is case in-sensitive. This field will be concatenated with the dial
string. (T)