A SERVICE OF

logo

DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Additional Maintenance Procedures
6-43Automatic Transmission Measurement System (ATMS)
6
Normally you should invoke only the full or supervision tests. The other options
are provided mainly for use in setting up an ATMS schedule. Which tests are run
depend on the type of TTL at the far end to which the test call is made. The
following table shows which tests are run for each type of TTL. Command syntax
is as follows:
test analog-testcal
trunkgroup#/| member#| port UUCSSpp | boardUUCSS
[full | supervision | no-selftest | no-return-loss | no-st-or-rl]
[repeat#][schedule]
Input Parameters
Different TTLs have different measurement capabilities and you will need the
following information about specific TTL types. This table does not include the
self-test nor does it distinguish between measurements for different test tone
levels.
trunk
addresses
You can specify a single trunk or several trunks by using
trunk
,
port
, or
board
addresses. These parameters are
described in the introduction to
Chapter 8, ‘‘Maintenance
Commands’’. If you enter a trunk group number without a
member number, all members of the group are tested.
full This executes the most comprehensive test call available
using the administered test set type.
“Full“is the default.
supervision This test takes about 10 seconds and simply confirms the
presence of testing capability at the far end.
no-selftest This executes the full test, but skips self test sequences.
This saves about 20 seconds on the type 105 transmission
test and has no effect on type 100 and 102 transmission
tests.
no-return-loss This executes the full test, but skips return loss sequences.
This saves about 20 seconds on the type 105 transmission
test and has no effect on type 100 or 102 transmission tests.
no-st-or-rl This executes the full test, but skips the self test and the
return loss sequences. This saves about 40 seconds on the
type 105 transmission test and has no effect on type 100 or
102 transmission tests.
repeat # This specifies repeating the tests up to 99 times. The default
is a single run of the tests.
schedule This qualifier brings up a form for scheduling execution of
the test at a later time. This is not the same as setting up an
ATMS Test Schedule, which is described above.