June 1999
Maintenance Object Repair Procedures
9-1512STBY-SPE (Standby SPE Maintenance)
9
Table 9-571. TEST #858 Standby SPE Time-of-Day
Comparison Test
Error
Code
Tes t
Result Description/ Recommendation
1000
2029
ABORT Either of these codes indicates that the test cannot run because internal
resources cannot be allocated to read active clock.
1. Consult SYSAM service documentation for time-of-day clock tests.
1338 ABORT Test cannot run because a planned SPE interchange is pending.
1. Wait for the planned interchange to complete, then for handshake to come
up, then re-run test on newly standby SPE.
1339 ABORT Test cannot run because handshake communication is not up.
1. Wait 5 minutes and try test again. If handshake is still not up (you get a
1339), solve the handshake problem as described in
Resolving
Handshake Failure
1346 ABORT Test could not read standby SPE’s TOD clock.
1. Test standby SPE’s SYSAM and consult that section in this chapter.
1377 ABORT A-carrier SPE’s clock is not moving forward.
1. Test A-carrier SYSAM’s time-of-day clock according to SYSAM service
documentation.
1378 ABORT B-carrier SPE’s clock is not moving forward.
1. Test B-carrier SYSAM’s time-of-day clock according to SYSAM service
documentation.
2000 ABORT Effort to read the clock timed out.
1. Test each of the two SPE’s SYSAMs (test maint {1a|1b}) as described in
SYSAM service documentation. Once these all pass, repeat this test.
FAIL Standby TOD clock differs from active’s by more than 20 seconds.
1. Wait 1-minute; repeat the test. If test passes, there is no problem.
2. If test fails, use the lock-power-down approach to replace the TN1648
SYSAM circuit pack on the standby SPE. After the repaired standby SPE is
fully initialized (handshake has been re-established), repeat the test.
3. If the test fails again, run it again it 1-minute later. If it fails again, perform a
planned SPE interchange and wait for it to complete, Replace the standby
SYSAM pack with another new replacement pack. Note that this repair
procedure requires two extra SYSAM circuit packs.
PASS The two SPE’s TOD clocks are within tolerable limits of one another.
Continued on next page