DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-555DISK (MSS Disk Circuit Pack)
9
Disk Diagnostic Test (#813)
The Disk Diagnostic test causes the Host Adapter to send a SCSI send
diagnostics command to the DISK Drive circuit pack. This initiates a set of
device-dependent self-tests that are run as a unit. Failures can be for multiple
1350 ABORT Could not run the test on the Standby SPEShadowing not enabled.
1. When the standby is restored to service (use status spe to determine state
of standby) retry the command.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2500 ABORT Could not run the test on the Standby SPEInternal software error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
5102 ABORT Could not allocate the Mass Storage System to run this test
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, verify that the daily translation-save operation
is not in progress (issue the display system-parameters maintenance
command to display the time for scheduled maintenance and the "y/n"
option for saving translation daily).
NO
BOARD
The disk has been placed in the "uninstalled" state.
1. Verify that the disk drive is fully inserted and powered up.
2. Attempt a demand reset of the disk.
1
FAIL At least one of the firmware error counters was non-zero.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, replace the Disk circuit pack, issue the reset
disk command and perform the restore disk command. This will take up
to 1 hour for a complete restore.
3. If the test continues to fail, replace the MSSNET circuit pack.
PASS All of the firmware error counters were zero. Look at the results of other tests to
see if it is operating correctly.
1. See the MSS Error Actions Table at the end of the TAPE section.
Table 9-227. TEST #812 Disk Firmware Error
Counters Read and Clear Test — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page