DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-278status isdn-testcall
8
Output
Port
This field specifies the physical address of the ISDN-PRI B-channel.
Bit Error
Rate
The measured bit error count according to the comparison of the sent
and received bit pattern. The number is displayed in scientific notation.
Number of
Bits
The number of bits generated. The number is displayed in scientific
notation.
Block error
Rate
The measured block error count according to the comparison of the
sent and received bit pattern. The number is displayed in scientific
notation.
Number of
Blocks
The number of blocks generated. The number is displayed in scientific
notation.
Start Time
The time the test call started (dd/hh:mm).
Duration
Specified
The duration specified in minutes for how long the test call should run.
Valid durations are 1-120 (minutes) or blank (to indicate the default
amount of minutes was used to run the test).
Duration of
Test
The duration specified in minutes for how long the test call has been
running. A blank indicates that the default amount of time was used to
run the test.
Reason of
Termination
The reason of termination indicates why the test call has terminated.
Valid reasons of termination are "finished," "canceled," "overflow," "no
bits," "transmission," "internal fail," "data corrupt," and "in progress." A
termination reason of "finished" means the test finished in the specified
time. A termination reason of "canceled" means the test call has been
canceled with the "clear isdn-testcall" command. A reason of "overflow"
denotes that the bits transmitted have overflowed buffer allocation. A
reason of "no bits" means that no bits have been received because the
ISDN-PRI test call circuit connection is bad. A reason of "transmission"
means there has been a data transmission interruption, probably
caused from a power hit. A termination reason of "internal fail" specifies
that there is an internal error on the Maintenance/Test circuit pack. A
reason of "in progress" means the test is still running and a reason of
"data corrupt" is used for any other error condition.