DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-216ATM-INTF (TN2305/6)
9
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 23: ATM Expansion Interface circuit pack is administered
through a
change circuit-pack
command, but has not been inserted into
the system. Insert the circuit pack.
b. Error Type 125: A wrong circuit pack is located in the slot where this circuit
pack is logically administered. To resolve this problem, either remove the
wrong circuit pack or insert the logically administered circuit pack.
c. Error Type 217: The ATM circuit pack is physically present but has not
been given a personality. Remove the circuit pack or administer it using
the
add atm pnc
command or
add atm trunk
command.
LED Condition LED
Red Board is not healthy Solid on never off
Red
Green
Board is in the processes of booting Red: solid on
Green: 200 ms on 200 ms off
Green Maintenance is running tests on the
board
Solid on (off when
maintenance completed)
Yellow Fiber LOS 100 ms on, 100ms off
Yellow Signal to the ATM switch is down 500 ms on, 500 ms off
Table 9-93. ATM-INTF Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
23(a) 0 None WAR OFF
125(b) None MIN ON
217(c) 0 None WAR OFF