![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg24f.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-280status link n
8
Output
The following display shows a typical result when
status journal-link
wakeup-log
is entered.
status link n
(csi, si, r models with C-LAN circuit pack - Ethernet connection)
This command displays:
■ static information about the link
■ the modem used, connect speed, and protocol information
■ a counter of CHAP failures for PPP links
■ time information for PPP and Ethernet links (includes the time of the last
reset, the last hour start time, and end time for the error counter statistics).
The same information that is displayed by the status link command can also be
invoked with:
■ status pgate-port for PGATE links
■ status clan-port or netstat link n for C-LAN links.
Link State
The operational status of the link as follows:
up
The link is established and is capable of supporting the application.
This is the normal operational state.
down
The link is physically down.
extension not administered
An extension number for the printer
administered has not been assigned on the hospitality system
parameters.
Maintenance
Busy
Whether there is any maintenance testing being performed upon the
link.
status journal-link wakeup-log SPE A
JOURNAL LINK STATUS
Link State: down
Number of retries: 1
Maintenance Busy? no