![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/07/207ea955-b0a5-4690-afdf-8b9461a5122e/207ea955-b0a5-4690-afdf-8b9461a5122e-bg43c.png)
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-400CLAN-BD (Control LAN Circuit Pack)
9
Packet Interface Test (#598)
This non-destructive test checks the packet bus interface circuitry on the CLAN
circuit pack. Test failure indicates faulty circuit pack.
Table 9-167. TEST #597 Invalid LAPD Frame Error
Counter Test
Error
Code
Tes t
Result Description/ Recommendation
2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the test fails again, replace the circuit pack.
2100 ABORT Could not allocate the necessary system resources to run this test.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 5 times.
1-10 FAIL The circuit pack detects LAPD frame errors. The error code indicates the
value of the on-board error counter.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the test continues to fail, execute the Packet Interface Test (#598) (test
board UUCSS long).
3. If Packet Interface Test (#598) fails, refer to Packet Bus repair procedures.
PASS Circuit pack detects no errors.
Continued on next page
Table 9-168. TEST #598 Packet Interface Test
Error
Code
Tes t
Result Description/ Recommendation
2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the test fails again, replace the circuit pack.
Continued on next page